Turbine Water Meter for cold water up to 40 °C
for hot water up to 130 °CPN25/40, DN 50 … DN 300
Technical Data:
Performance Table 40 C
Nominal Diameter | DN | 200 | 250 | 300 | |
Size of meter (acc. To EEC) | Qn | 250 | 400 | 600 | |
Maximum peak flow (few minutes) | Qmax | m3/h | 800 | 1200 | 2000 |
Continues Flow +/- 2% | Qn | m3/h | 550 | 750 | 1000 |
Transition Flow +/- 2% | Qt | m3/h | 6.0 | 12 | 15 |
Min. Flow +/- 5% | Qmin | m3/h | 4.0 | 6.0 | 12 |
Starting Flow | 1.8 | 3.0 | 9.0 |
For DN 50-150 please see MeiStream PN 40
Performance Table 130 C
Nominal Diameter | DN | 50 | 80 | 100 | 150 | 200 | 250 | 300 | |
Size of meter (acc. To EEC) | Qn | 15 | 40 | 60 | 150 | 250 | 400 | 600 | |
Maximum peak flow (short time) +/-2% | Qmax | m3/h | 30 | 90 | 140 | 300 | 500 | 1000 | 1200 |
Continues Flow | Qn | m3/h | 15 | 45 | 70 | 150 | 250 | 500 | 600 |
Transition Flow +/-3% | Qt | m3/h | 1.8 | 3.2 | 4.8 | 12 | 20 | 45 | 50 |
Min. Flow +/- 5% | Qmin | m3/h | 1.0 | 1.4 | 2.0 | 4.5 | 8 | 25 | 30 |
Starting Flow | m3/h | 0.25 | 0.35 | 0.6 | 1.7 | 2.0 | 10 | 15 |