SENSUS Water Meter WS-Dynamic DN50~DN150

SENSUS WS-Dynamic

Technical Data:

Performance data WS-Dynamic for Hot Water

Nominal Diameter   DN 50 65 80 100 150
Size of meter (acc. To PTB-A22)   Qn 15 25 40 60 150
Maximum peak flow (few minutes) +/-2% Qmax m3/h 30 60 85 125 300
Continues Flow +/-2% Qn m3/h 15 25 40 60 150
Transition Flow +/-2% Qt m3/h 1.5 2.5 2.5 4.0 12
Min. Flow +/- 5% Qmin m3/h 0.25 0.30 0.30 0.50 0.80
Starting Flow     0.06 0.7 0.10 0.15 0.50

Performance data acc. to PTB-A22 – Specificatrion Class C

Nominal Diameter   DN 50 65 80 100 150
Size of meter (acc. To PTB-A22)   Qn 15 25 40 60 150
Maximum peak flow (short time) +/-2% Qmax m3/h 30 50 80 120 300
Continues Flow  Qn m3/h 15 25 40 60 150
Transition Flow +/-3% Qt m3/h 1.5 2.5 4.0 6.0 15.0
Min. Flow +/- 5% Qmin m3/h 1.2 2.0 3.2 4.8 12.0